Retail Leasing Architectural Check List
- Location, Location, Location
- Space usability for proposal:
 |
Bldg. code compliance
Allocations/dimensions for new use needs and efficiency
|
- ADA compliance:
 |
Availability of past SF Building approved ADA Permit dwgs.
Entrance door size, 5' level landing on both sides, jamb side space, door sidewalk clearance, closer/pressure, ramp slope, lift size
Sidewalk - curb to entrance door slope
Floor level differentials over 1/2" -
Access corridor widths Ð 44" min.
Toilets - (1 or 2) in space, or on same floor in building
Elevator - size, controls
Etc. - door hardware, switches, signage, ?
|
- Utilities - electrical, gas, plumbing:
 |
Building - amounts, sizes and locations
Space - lighting, electricity, phones,
Space conditioning - heat, air
Sprinkler system -
Billing system -
|
- Restaurants:
 |
Hood Ð existing (type 1 or 2) or ability to install economically
Electric - power and phases
Gas - supply (2"?)
Grease trap - existing or feasibility
Garbage - availability and system etc.
Health code permits -
|
- Signage amount and type permitted:
- Hours of usage and access - permitted or required
- Anticipated building changes
|